SV 258 PRO is an outdoor monitoring system based on SVAN 958A Class 1 sound level meter. The portable and battery powered station can be used for a variety of monitoring applications including construction site monitoring, tunneling and blasting. The IP 65-rated case contains a lead-acid battery which operating time can be easily extended by connecting an external battery or small solar panel. The intelligent charging unit enables use of a solar panel without expensive controllers and heavy batteries. The case is fitted with very robust, waterproof connectors (military standard) and comes with an IP 65 external power supply. The system uses a low-noise, hermetically sealed tri-axial piezoelectric accelerometer enabling the outdoor use without additional enclosures. The accelerometers' signal ground is insulated from the mounting surface and outer case to prevent ground loops. All accessories fit conveniently into a second carrying case. About Features The system provides broad-band vibration results such as RMS and Peak or Peak-Peak. Optionally it can use FFT analysis for determination of dominant frequency used for comparison with the BS and DIN norm curves. The broad-band noise results can be recorded simultaneously in three acoustic profiles, which enable measurements to be taken with 3 different filters (e.g. A, C, Z) as well as 3 different detector time constants (e.g. Fast, Slow, Impulse). The SVAN 958A can be easily removed from the case and used as hand-held vibration and sound level meter. The monitoring station uses the 3G modem for the remote communication with Internet. SvanNET, the relay server, supports the connection between PC and station allowing the usage of all types of SIM cards with the system, regardless if they have public or private IP. The connection over the SvanNET gives access to the status of the noise monitoring station via mobile phone or tablet.
-Remote Communication 3G modem
-Power Supply DC power supply / charger 11 V ÷ 30 V (waterproof)
-Internal battery 17 Ah / 12 V
-Secondary external battery 33 Ah / 12 V (optional)
-Solar panel (optional)
-Operating time on battery 3 days with continuous modem transmission
-7 days with modem switched off
-Test Conditions: meter mode, display dimmed, 10 ms time-history logger
-Microphone protection kit SA 271 outdoor protection kit (optional)
-Environmental Conditions Temperature -10 °C ÷ +50 °C
-Dimensions 420 x 340 x 210 mm (without antenna and cables)
-Weight Approximately 9 kg including battery
-Accelerometer SV 84 triaxial high sensitivity (1 V/g)
-Meter Mode RMS, VDV, MTVV or Max, Peak, Peak-Peak, Vector, A(8), Dose, ELV, EAV
-Profiles Per Channel 2 (in Ground Vibration mode)
-Analyser (optional) 1/1 octave real-time analysis
-1/3 octave real-time analysis
-FFT analysis up to 1600 lines in a selectable frequency band
-Time domain signal recording to WAV format
-Filters In Profile 1 HP1, HP3, HP10, VEL1, VEL3, VEL10, VELMF, DIL1, DIL3,
-DIL10, KB, Wk, Wd, Wc, Wj, Wm, Wh, Wg, Wb, Wv
-Filters In Profile 2 VEL1, VEL3, VEL10
-RMS & RMQ Detectors Digital true RMS & RMQ detectors with Peak detection, resolution 0.1 dB
-Detector Time Constants From 100 ms to 10 s
-Accelerometer SV 84 triaxial high sensitivity (1 V/g)
-Measurement Range SV 84: 0.0005 ms-2 RMS ÷ 50 ms-2 PEAK (accelerometer dependent)
-Frequency Range SV 84: 0.2 Hz ÷ 3 700 Hz (accelerometer dependent)
-Standards Class 1: IEC 61672-1:2002
-Profiles Per Channel 3
-Meter Mode SPL, Leq, SEL, Lden, Ltm3, Ltm5, Statistics - Ln (L1-L99),
-LMax, LMin, LPeak
-Analyser (option) 1/1 octave real-time analysis, (Class 1, IEC 61260)
-1/3 octave real-time analysis, (Class 1, IEC 61260)
-FFT analysis up to 1600 lines in selectable frequency band
-Weighting Filters A, C, Z, G
-RMS Detector Digital true RMS detector with Peak detection, resolution 0.1 dB
-Detector Time Constants Slow, Fast, Impulse
-Microphone (option) MK 255, Class 1, 50 mV/Pa, prepolarised 1/2"
-Preamplifier (option) SV 12L detachable
-Measurement Range 16 dBA RMS ÷ 140 dBA Peak (Total Dynamic Range)
-Linearity Range 26 dBA RMS ÷ 140 dBA Peak (IEC 61672)
-Frequency Range 0.5 Hz ÷ 20 kHz (microphone dependent)
-MK 255: 3.5 Hz ÷ 20 kHz
- Classe di protezione IP 65 (microfono escluso)
- Memoria Micro SD card da 4 GB (removibile & sostituibile con capacità superiori)
- Display a colori, 96 x 96 pixel, tipo OLED
- Interfacce USB 2.0 cliente
- Alimentazione 4 batterie alcaline AAA o NiMH ricaricabili
durata 16h ÷ 24h (a secondo dell’uso)
- Interfaccia USB 100 mA HUB
- Condizioni ambientali Temperatura da -10 ºC a 50 ºC
- Umidità fino a 95 % UR, senza condensa
- Dimensioni 232,5 x 56 x 20 mm (con microfono e preamplificatore)
- Peso Circa 225 grammi con batterie
via Tertulliano, 37 - 20137 Milano, c.f/p.iva 12641870154
Tel. 339 1245529 - novitec@novitec-expo.it