Rumore Fonometri

SVAN 271 lite
Noise Monitoring Station

SV 271 LITE is an outdoor monitoring system based on typeapproved SVAN 971 Class 1 sound level meter. The IP 65-rated case contains a lead-acid battery which operating life can be easily extended by connecting an external battery or a solar panel. The intelligent charging unit enables use of a solar panel without expensive controllers or heavy batteries. The case is fitted with very robust, waterproof connectors (military standard) and is supplied with an IP 65 external power supply. The light-weight microphone protection kit can be easily installed on a mast with standard mounting threads. All accessories fit conveniently into a second carrying case. The system provides broad-band results such as Leq, Max, Min and Peak with all standard weighting filters together with an incredible time-history logging feature with two adjustable logging steps. The broad-band results can be recorded in three acoustic profiles which enable measurements to be taken with 3 different filters (e.g. A, C, Z) as well as 3 different detector time constants (e.g. Fast, Slow, Impulse). The SVAN 971 can be easily removed from the case and used as hand-held sound level meter.

- SVAN 971 il più piccolo Fonometro in classe 1
- Conforme alla IEC 61672-2002
- Valido per misure acustiche in ambienti di lavoro e ambientali
- I setup predefiniti e la sua ergonomia ne facilitano l’uso
- Setup editor effettuabile tramite software
- Misure per campo libero e campo diffuso
- Time History & Analisi Statistica
- Funzioni di dosimetria
- Filtri Real-time 1/1 & 1/3 d’ottava
- Registrazione Audio ed Eventi
- Commento vocale riferito alla misura in atto
- La memoria Micro SD permette una capacità praticamente illimitata
- Avvio automatico della calibrazione
- Display colore OLED ad altissimo contrasto
- Classe di protezione IP 65
- Tascabile, maneggevole, leggero e robusto
- Interfaccia utente friendly


-Standards Class 1: IEC 61672-1:2002
-Weighting Filters A, B, C, Z
-Time Constants Slow, Fast, Impulse
-RMS Detector Digital True RMS detector with Peak detection, resolution 0.1 dB
-Microphone ACO 7052E, 35 mV/Pa, prepolarised 1/2” condenser microphone
-Preamplifier SV 18 detachable
-Linear Operating Range 25 dBA RMS ÷ 140 dBA Peak (in accordance to IEC 61672)
-Total Dynamic Measurement Range 15 dBA RMS ÷ 140 dBA Peak (typical from noise floor to the maximum level)
-Internal Noise Level less than 15 dBA RMS
-Dynamic Range > 110 dB
-Frequency Range 10 Hz ÷ 20 kHz
-Meter Mode Results Elapsed time, Lxy (SPL), Lxeq (LEQ), Lxpeak (PEAK), Lxymax (MAX), Lxymin (MIN),
-LR (ROLLING LEQ OPTION), Ovl (OVERLOAD), Lxye (SEL), LN (LEQ STATISTICS), Lden,
-LEPd, Ltm3, Ltm5
-Simultaneous measurement in three profiles with independent set of filters (x) and detectors (y)
-Statistics Ln (L1-L99), complete histogram in meter mode
-Audio Recording (option) Audio events recording, trigger and continuous mode, 12 kHz sampling rate, wav format
-1/1 Octave Analysis (option) Real-time analysis meeting Class 1 requirements of IEC 61260,
-centre frequencies from 31.5 Hz to 16 kHz
-1/3 Octave Analysis (option) Real-time analysis meeting Class 1 requirements of IEC 61260,
-centre frequencies from 20 Hz to 20 kHz
-Data Logger Time-history logging of summary results, spectra with adjustable double logging steps
-down to 100 ms
-Memory MicroSD card 8 GB (removable & upgradeable up to 128 GB)


-Power Supply DC power supply / charger 11 V ÷ 30 V (waterproof)
-Internal battery 17 Ah / 12 V
-Secondary external battery 33 Ah / 12 V (optional)
-Solar panel (optional)
-Operating time on battery Up to 21 days
-Test Conditions: meter mode, display dimmed,
-100 ms time-history logger, continuous event recording
-Microphone protection kit SA 271 outdoor protection kit (IP 65)
-Environmental Conditions Temperature -10 °C ÷ +50 °C
-Dimensions 300 x 260 x 190 mm (without antenna and cables)
-Weight Approximately 9 kg including battery

Analizzatore
- Analisi in 1/1 ottava Analisi in real-time in classe 1, conforme alla di IEC 61260, da 31.5 Hz a 16 kHz (opzionale) contemporaneamente ai tre profili (SLM), registrazione time history e audio
- Analisi in 1/3 d’ottava Analisi in real-time in classe 1, conforme alla di IEC 61260, da 20 Hz a 20 kHz (opzionale) contemporaneamente ai tre profili (SLM), registrazione time history e audio


The option for 1/1 OR 1/3 OCTAVE REAL-TIME ANALYSIS allows the analysis of the noise
frequency contents. It can be activated at any time by entering an activation code.

The option of EVENT RECORDING works during measurement and is logged in parallel to time
history. Once downloaded to PC it can be played back. Settings such as triggers or recording
time are adjustable. It can be activated at any time by entering an activation code.

SvanPC++ Environmental Monitoring is designed for post-processing
of data recorded by monitoring station. The module offers a powerful calculator and
an automated noise event finder for noise source identification. Thanks to its “Projects”
functionality, SvanPC++_EM allows to combine and compare data from multiple measurements
as well as create and save reports in MS Word™ templates. The module can be activated at any
time by entering the activation code.

Novitec s.a.s.

via Tertulliano, 37 - 20137 Milano, c.f/p.iva 12641870154
Tel. 339 1245529 - novitec@novitec-expo.it